LT Liquid Level Gauge & Transmitter

Click here to download PDF 
 
Working pressure manufacturing according to

PED 97/23/CE (Lloyd’s Register Certificate Nº 031)
Simply constructed and resistant to adverse conditions of
temperature and pressure. Materials in EN 1.4404 (SS 316L),
PVC, PP, PVDF or PTFE for most applications in industries
such as:

• Chemical, petrochemical and other processes
• Refrigeration, Retorts and Heat Treatment
• Boilers, marine & industrial
• Evaporators & Condensers
• Storage Tanks

Features

• Full process isolation, no risk of leakage
• Alarms contacts adjustable over the full range
• Clear indication with magnetic float or magnetic strips
• Transmitter output 0...4-20 mA
• Excellent chemical and mechanical resistance

Operation
A vertical measuring chamber, connected to the tank at
each end, contains a magnetic float that rises and falls
with the liquid level. An indicating chamber is attached, but
not directly connected, to the measuring chamber. The
indicating chamber contains a magnetic strips indicator
or magnetic float that follows the position of the float in
the measuring chamber to provide an indication of the
tank level.

Adjustable contacts, actuated by the float’s magnetic field,
can provide switch points for control or alarms. A sensor
detecting the float position can provide a 4-20 mA signal
for proportional control.
(On request HART, PROFIBUS, FIELDBUS protocol)

  • Features
  • Operation
Features:
Full process isolation, no risk of leakage. 
Alarms contacts adjustable over the full range. 
Clear indication with magnetic float or magnetic strips. 
Transmitter output of 0...4-20 mA. 
Excellent chemical and mechanical resistance.
Operation 
A vertical measuring chamber, connected to the tank at each end, contains a magnetic float that rises and falls with the liquid level. An indicating chamber is attached, but not directly connected, to the measuring chamber. The indicating chamber contains a magnetic strips indicator or magnetic float that follows the position of the float in the measuring chamber to provide an indication of the tank level.

Adjustable contacts, actuated by the float’s magnetic field, can provide switch points for control or alarms. A sensor detecting the float position can provide a 4-20 mA signal for proportional control.or full details.e.

Related Products

LT10 Level Gauge

Learn More

LP80 Level Transmitter

Learn More

LE70 Level Transmitter

Learn More

Address

Badminton Close, Naunton Lane, Leckhampton, Cheltenham, Gloucestershire GL53 7BX UK Tel: +44 (0) 1242 243006  Fax: +44 (0) 1242 222487 e-mail: info@nixonflowmeters.co.uk

Testimonial

Your co-operation in pulling out all the stops to supply a replacement turbine flowmeter has meant we have not lost any production time. I am a great believer that such service should not go unrecognised.

Director of Engineering
Delta Biotechnology

Connect with us

 

Copyright 2019 by Nixon Flowmeters
  • Back to top